欧美性巨大╳╳╳╳╳高跟鞋,亚洲heyzo专区无码综合,久久自己只精产国品,人妻无码αv中文字幕久久琪琪布

全國服務(wù)咨詢熱線:

15618996225

當(dāng)前位置:首頁  >  產(chǎn)品中心  >  太赫茲  >  太赫茲功率計  >  Mm-Wave power meter高靈敏度毫米波功率計

高靈敏度毫米波功率計

簡要描述:高靈敏度毫米波功率計Features
0.01-220 GHz operating frequency
High sensitivity
Up to 55 dB dynamic range (0.1uW-30mW)
Small measuring time (< 1 sec)
RS-232, GPIB interface
SCPI protocol

  • 產(chǎn)品型號:Mm-Wave power meter
  • 更新時間:2025-03-12
  • 訪  問  量:859

產(chǎn)品簡介

品牌其他品牌產(chǎn)地類別進(jìn)口
應(yīng)用領(lǐng)域農(nóng)林牧漁,電子/電池,汽車及零部件,電氣

詳細(xì)介紹

 

高靈敏度毫米波功率計Features  
  • 0.01-220 GHz operating frequency

  • High sensitivity

  • Up to 55 dB dynamic range (0.1uW-30mW)

  • Small measuring time (< 1 sec)

  • RS-232, GPIB interface

  • SCPI protocol

高靈敏度毫米波功率計Applications  
  • Recommended for use by Rohde & Schwarz

  • Measurements of power level of mm-wave signal

  • Test equipment

Description

The DPM-xx is a single-channel average power meter for RF to millimeter wave frequencies that measures absolute power from 10 MHz to 220 GHz.

DPM-xx Power Meters display measured power in milliWatts, microWatts or dBm, and also display the user-entered signal frequency in GHz. Easy operation is ensured with automatic zeroing, automatic sensor recognition and a calculation factor table stored in the memory of each power sensor.

Their compact size, precise accuracy, reliability and inexpensive pricing make our DPM-xx Power Meters attractive assets for design engineering, equipment manufacturing, field engineering and research.

ELVA-1’s ZBD-series Zero-Biased Detectors are used as the power sensors for our DPM Power Meters.To cover the range from 10MHz to 220GHz band, we offer one coaxial (10 MHz-26.5 GHz) and 9 waveguide power sensors (26.5-220 GHz in waveguide bands), sold separay.

Based on Schottky Barrier Diode technology, our ZBD power sensors provide high sensitivity, fast measurement speed and quick response to changes of input power. To extend the dynamic range of diode power sensors above their square law region, a correction factor is used. The amplitude and frequency curves for each individually-calibrated power sensor are stored in the sensor’s EEPROM. When a sensor is connected to a DPM control/display unit, the control/display unit automatically recognizes that sensor’s characteristics. The typical curves for amplitude and frequency transfer characteristics at W-band are shown on the reverse.

Measured average power is displayed on a 2-line LCD screen, at a measurement rate of 2 times per second or faster. For power measurements below 10-100mW (depending on frequency band), each sensor is supplied with a full-band isolator. For power measurements above those levels (as high as 300mW-1Watt), optional directional couplers are available.

Every DPM-xx is equipped with an RS-232 port for control and measurement data exchange with a PC. An internal GPIB interface board is available as an added option. On special request we can also provide a dual channel power meter of DPMD-XX series with two independent measurement channels.

Since the control/display unit and power sensors are sold separay, customers only need one DPM control/display unit to interface with all 10 of our sensors. To obtain power measurements over a multi-waveguide frequency range, order one DPM control/display unit and several adjacent-band sensors.  Because the standard ELVA-1 DPM control/display unit is a single-channel meter, only one power sensor can be used at one time.

 

DPM-XX Key Features and Specifications

- Display readings: milliWatts, microWatts or dBm

- Maximum measuring rate: up to 50 times per second, default 2 times per second (set at factory)

- Frequency Range: 10 MHz to 220 GHz

- Min. measured Power: 0.1 microWatt (depending on frequency band)

- Dynamic Measurement Range: 55dB max. (depending on frequency band)

- Frequency step: 10 MHz

- SCPI or ELVA’s command protocol

- RS-232, GPIB interface

- Calibration accuracy ±0.04 dB (log) or ±1%

- Power Sensor Calibration: Individually calibrated, with amplitude and frequency curves in flash memory

- If a valid signal frequency is not entered before measuring power, maximum measurement error will be ±1.5dB for Ka, Q, U, V bands, ±2.0dB for E, W bands, and ±2.5dB for F, D bands, based on calibration curve flatness.

Model Number DPM-C DPM -28 DPM -22 DPM -19 DPM -15 DPM -12 DPM -10 DPM -08 DPM -06 DPM -05
Frequency Band Ka Q U V E W F D G
Frequency Range, GHz 0.01-26.5 14757 33-50 40-60 50-75 60-90 75-110 90-140 110-170 140-220
Input Waveguide/Impedance 50 Ohm, Coaxial WR-28 WR-22 WR-19 WR-15 WR-12 WR-10 WR-08 WR-06 WR-05
Wavequide Flange/Connector SMA, male UG-599/U UG-383/U UG-383/U-M UG-385/U UG-387/U UG-387/U-M UG-387/U-M UG-387/U-M UG-387/U-M
Dynamic Range, dB (max) 50 55 55 55 55 55 55 55 50 40
Min Measured Power Level, dBm -33 -43 -43 -43 -43 -43 -40 -40 -35 -25
Measurement Rate (default), times per sec 2 2 2 2 2 2 2 2 2 2
VSWR (power sensor) 1.2:1 1.3:1 1.3:1 1.3:1 1.3:1 1.4:1 1.4:1 1.4:1 1.4:1 1.4:1

Available operating power options: 220 VAC, 110/100 VAC, or battery power (for portable version).

 

產(chǎn)品咨詢

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細(xì)地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結(jié)果(填寫阿拉伯?dāng)?shù)字),如:三加四=7

全國統(tǒng)一服務(wù)電話

021-62209657

電子郵箱:sales@eachwave.com

公司地址:上海市閔行區(qū)劍川路955號707-709室

業(yè)務(wù)咨詢微信

亚洲av永久无码精品三区在线 | 国产免费无码又爽又刺激A片| 野花韩国电影免费观看在线 | 国产精品亚洲av无人区一区| 粗大挺进朋友人妻淑娟| 中文字幕日韩欧美一区二区三区| 亚洲国产成人精品无码区花野真一 | 欧美激情精品久久久久久| 热re99久久精品国产99热| 欧美精品色婷婷五月综合| 曰本无码人妻丰满熟妇啪啪| 久久无码专区国产精品s| 日本片在线看的免费网站| 一本久久知道综合久久| 久久亚洲精品中文字幕| 国产精品爽黄69天堂A片| 99久久国产精品人妻无码| 欧美重囗味成人无码区| 国内少妇人妻偷人精品XXX| 中文字幕久精品免费视频 | 国产欧美日韩精品丝袜高跟鞋| 国产午夜精品一区二区三区嫩草| 欧美R级A片成人片不可撤销 | 欧美丰满熟妇乱XXXXX网站| 色欲老女人人妻综合网| 免费人妻精品一区二区三区| 国产性一乱一性一伧| 亚洲 都市 校园 激情 另类| 欧美+日本+国产| 5566视频一区二区三区| 蜜臀AV性久久久久蜜臀AⅤ麻豆| 国产AV人人夜夜澡人人爽麻豆 | 无码精品日韩专区第一页| 亚洲一区爱区精品无码| 国产午夜福利久久精品| 国产另类ts人妖一区二区| 亚州日本乱码一区二区三区| 好爽…又高潮了毛片免费看| 亚洲色欲久久久久综合网| 狂猛欧美激情性xxxx大豆行情| 国产精久久一区二区三区|